THE DEFINITIVE GUIDE TO DP50RB

The Definitive Guide to Dp50rb

The Definitive Guide to Dp50rb

Blog Article

Assist 4D probe; identify the probe through the ID code; swap the 4D drive signal via the  electrical relay to make the 4D probe operate Ordinarily. 4.2.2 Most important board The leading board could be divided into two elements: entrance-conclusion of the principle board and back again-end of the primary board.

Greatest 4 periods tasking for 1 transmitted beam, causing exceptional time resolution and better body price.

Get an entire and extended perspective of your anatomical construction by way of panoramic imaging coupled with velocity indication and ahead/backward scan capacity generating scanning much easier, smoother and much more controllable.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Simply click Agree and Carry on to accept cookies and go on to the site or click on Additional information to see specific descriptions of the types of cookies and pick out irrespective of whether to accept specified cookies while on the positioning.

Mindray’s new era of black & white ultrasound system, DP-50 Professional, is equipped with advanced imaging systems allowing for deeper penetration and more quickly picture acquisition with better resolution.

The chapter materials the tactic to confirm main purpose and effectiveness of merchandise. This can be only employed for reference, not preventive execution. Perform examining and screening of the component shall be carried out by Mindray services engineers as well as user with each other. Web page sixty six: Normal Examination

Uncover better diagnostic details through prolonged perspective of the anatomical framework on all convex probes.

Analyzing sufferers in nowadays’s demanding natural environment involves revolutionary technological know-how that enables clinicians to help make quick and assured diagnoses. The versatility from the DP-fifty expands your clinical utility whilst assisting to increase patient care.

5.two.three Geometric positioning precision Longitudinal geometric positioning accuracy  Take a look at Stage: Do changes as the way in screening the maximum depth. Report the space by 20mm Just about every phase around the longitudinal targets line utilizing the measurement caliper; Pick the value with the greatest mistake (to 20mm), determine the precision using the formulation beneath Dp50rb The measurement caliper must be positioned with the upper fringe of the target, Take note:... Web site 79 Transverse geometric positioning precision  Examination Action: Address the scan surface of your phantom with water or couple gel, Carefully Make contact with the probe with the scan surface Change the depth, producing the transverse targets to become shown while in the picture. Adjust the focus place to become posited beside the transverse targets (the typical isn't apparent) Adjust parameters like achieve, TGC, making Every single transverse targets to generally be clearly shown. Site eighty 5.5.2.4 Blackout Area Take a look at Step: Protect the scan surface area of the phantom with water or couple gel, Carefully Call the probe With all the scan area Adjust the depth at a lower price, and set the main focus at the nearest spot to the scan floor. Reduce the value of parameters like AP, Get right until the track record sounds just might be viewed. Web site eighty one: Program Up grade And Maintenance

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

Be aware: Prior to uploading the log, be sure the ultrasound technique has long been linked to community, usually, the process may alert “could not connect to server” The server (smtp.

Be aware: In advance of inserting the connector in the probe port, inspect the connector pin. If the pin is bent, don't utilize the probe right up until it has been inspected / fixed / changed. Putting in Peripherals With the designs with the supported peripherals, be sure to check with “2.